- Latest News: QuadTech Announces the New Guardian 1000 Series of Hipot Testers
- The Reference Desk: Application Notes
- Medical News: IEC60601-1 5th article in a Series of 8
- Integrator Partnership News: QuadTech Partners with IBIS Machine Design
- Useful Website: Marshall Brain's HowStuffWorks.com
- Product Spotlight: QuadTech's 1900 Series Receives Overwhelming Acceptance Across Many Industries
- Feedback and Unsubscribe Instructions
|
|
Latest News:
|
|
QuadTech Announces the New Guardian 1000 Series of Hipot Testers
The Price Performance Industry Leader
|
- Large Graphical Display
- High AC Charging Current to 30mA
- Compact Bench Top Unit
- 8 Channel Built-in Scanner (Model 1030S)
- RS232 Interface Standard
|
|
For additional product information, click here.
Back to Top
|
|
The Reference Desk:
|
|
1920 Used in Eddy Current Sensing
The 1920 LCR Meter is an all-purpose precise instrument that has quite an interesting application in measuring the conductivity of sensor plates. It's back to electromagnetics class for a short discussion on eddy current properties and it's affect in transformers. Physics is cool and science rules.
Ensuring the Safety of Medical Electronics
James Richards, Marketing Engineer, takes a look at electrical safety testing of medical products from the standpoint that safety standards alone do not ensure the device is safe. That safety is as much a function of product design as it is the manufacturer's test program.
Determining if a Device is Connected Using a Low Trip Limit
Have you ever had trouble powering up an electronic device and someone comes along smartly inquiring, "Well, did you plug it in?" This happens to most of us, but when you're dealing with a DUT connected to a hipot tester and the application of high voltage, prudence comes in the form of a 'low trip limit'.
Power Factor of a Capacitor
Is there a difference between the dissipation factor and power factor of a capacitor? Yes and no. Investigate what physical and electrical properties of a capacitor influence the dissipation factor equation.
Back to Top
|
|
Medical News:
|
|
EST 101 (IEC60601-1 and basic electrical safety tests) - 5th article in a Series of 8
Check out this 5th installment of the IEC60601-1 Series for definitions of the electrical safety tests terms called out in IEC60601-1. It also provides a short course in the four basic electrical safety tests (ground, voltage, current and resistance) and illustrates their respective setups.
|
Back to Top
|
|
Integrator Partnership News:
|
|
QuadTech Partners with IBIS Machine Design, Inc.
IBIS Machine Design, based in Burlington, North Carolina, is a turnkey design and build company specializing in automated assembly equipment, end of line test equipment, factory automation, and control solutions. They have built machines for a wide variety of companies including: DeWalt, Pepsi, Black & Decker, NIST and Nabisco to name a few. Fast turnaround, attention to detail, resourcefulness, and the ability to provide inventive solutions makes IBIS Machine Design an excellent consideration for your next project.
ECI Becomes ISO 9001 Certified
Collierville, TN 1/30/02 - Electrical Controls, Inc. has been assessed by AOQC Moody International, Inc. in respect of their Quality Management System and found to comply with ANSI/ISO/ASQC Q9001:2000.
Back to Top
|
|
Useful Website:
|
|
Marshall Brain's HowStuffWorks
HowStuffWorks is a media company that is internationally recognized as the leading provider of information on how things work. Visit www.howstuffworks.com for in-depth articles that explain the world from the inside out to millions of readers every month. Don't know where to start? Search for Inductors, Capacitors, or even how social security numbers work? It's all there.
Back to Top
|
|
Product Spotlight:
|
|
QuadTech's 1900 Series receives overwhelming acceptance in a number of Industries. Here are some highlighted application notes explaining the uses and applications in a few of the industries.
Low ESR Capacitor Measurements
What is ESR and how does it affect capacitor measurements? Investigate the technology and trends that have driven the manufacture of capacitors with lower equivalent series resistance. Factors affecting total loss and methods for making accurate measurements are discussed also.
Analyze This Inductor
Inductor properties, like capacitor properties, can be difficult to measure without performing analysis under real-time operating conditions. The measured inductance is dependent on the current flowing through the inductor. Knowing the precise current, being able to bias it or hold it constant will help fully characterize the inductance of the device under test.
Testing Automotive Engine Oxygen Sensors Using the 1900 Series Precision LCR Meter
The 1900 Series instrument has another interesting application in the testing of the C value in the capacitive element of an oxygen sensor used in automotive engines. Tests on the he ceramic capacitor inside the oxygen sensor are done after sensor assembly due to the fragility of the ceramic element.
Measurement of Dielectric Constant and Loss
Need to measure the dielectric constant of a solid or liquid? Integrate a QuadTech 1900 Series Precision LCR Meter and a Dielectric Product's Type LD-3 Cell for a complete measurement solution. The contact method, air gap method and two-fluid method are discussed and illustrated plus calculations are given for determining the sample's capacitance.
Back to Top
|
|
Feedback & Unsubscribe Instructions:
|
|
Feedback
|
|
If you have any questions, comments or feedback about this newsletter, please send us a note - Marketing@quadtech.com
|
Back to Top
|
|
|
|
|
Home Customer Support Contact Us Privacy Policy Shopping Cart Site Map
Copyright © 2007 QuadTech. All rights reserved. Site designed and maintained by Sagebridge Solutions |